SIBELSOUND DUO is a 2-channel audiometer that has been developed by the R&D&i department at SIBELMED, in compliance with the European Directive on Medical Devices and the highest quality standards.
The portable and lightweight features of the SIBELSOUND DUO makes the device ideal for performing audiometries in any setting.
The audiometer has 2 options for exporting test files directly via Ethernet in standard formats (PDF, XML and CSV):
SIBELSOUND DUO can be used to carry out audiometry tests in automatic mode, which requires minimum intervention of the technician.
This mode guarantees that the test is conducted correctly, as it follows the automatic Hug hson-Westlake audiometry protocol.
SIBELSOUND DUO can be connected to the audiometer’s W50 software via USB, which allows the user to view, store, transfer and analyze audiometry tests.
Perform audiometries in real time.
Import the tests performed with the audiometer.
View audiometry tests.
Audiometry chart with test results.
Compare tests conducted on the same patient.
Consult the diagnosis.
Customized reports.
Print reports.
Download tests in PDF and XML.
Management of different databases.
Upgrades of the SIBELSOUND DUO firmware.
Compatible with all Sibelmed audiometers.
Valid for Windows 7, 8.1 and 10.
Air conduction
Air conduction
Bone conduction
Masking
Technical Specifications | |||
---|---|---|---|
A Model | AOM model | ||
Audiometer type, as specified in EN 60645.1 | Type 4 (Screening) | Type 3 (Basic diagnosis) | |
Pure tone threshold audiometry by air conduction | Yes | Yes | |
Pure tone threshold audiometry by bone conduction | — | Yes | |
Masking | — | Narrow Band Noise |
Channels | 2 | ||
Tone | Pure and Warble (FM) | ||
Continuous and Pulsating | |||
Inverted tone | Yes | ||
Noise increase (dB) | 5 | ||
Air conduction frequencies (Hz) | 125 – 250 – 500 – 750 – 1000 – 1500 – 2000 – 3000 – 4000 – 6000 – 8000 | ||
Bone conduction frequencies (Hz) | — | 250 – 500 – 750 1000 – 1500 – 2000 3000 – 4000 – 6000 | |
Intermediate frequencies (Hz) | 125 – 750 – 1500 | ||
Air conduction levels (dB HL) | Max. 100 / Min. -10 | ||
Bone conduction levels (dB HL) | — | Max. 65 / Min. -10 | |
Masking (dB HL) | — | Max. 100 / Min. -10 | |
Intercom | Yes | ||
Calculation of hearing loss | Yes | ||
Diagnoses | Council, IMSS Mexico, ELI, SAL, Klockhoff |
Measurements | 236 x 197 x 77 mm. | ||
Weight | 600 g. | ||
Screen | Color touchscreen | ||
95×54(mm.) · 480×272(pix.) | |||
Internal database | > 1,000 tests | ||
Unlimited patients | |||
Connectivity | USB –> PC connection for software Ethernet –> Connection for data export |
||
Power Supply | External power supply (Input: 100-240 Vac, Output: 12 Vdc) 4 AA 1.5V batteries • 4 Ni-MH rechargeable batteries |
User Manual
03658 USB connection cable for PC
03024 W50 demo mode software
01807 Patient response button
09460 Set of DD45 headphones
02258 Set of headphones, bone conduction 871W (AOM Model)
09489 Carry case
09459 External power supply
09134 Automatic audiometry
09505 Data export via Ethernet
07886 cable induded
02303 W50 Software License
02260 Set of TDH39 air conduction headphones
03078 Sound suppressors for air conduction (Audiocups)
+34 93 436 00 08
www.sibelmed.com
export@sibelmed.com
SIBEL, S.A.U.
c/ Rosellón, 500 bajos
08026 BARCELONA (Spain)