DATOSPIR touch is a spirometer developed by the SIBELMED R&D&I department.
3 available operating modes, OCCUPATIONAL MEDICINE, PRIMARY HEALTHCARE AND PULMONARY FUNCTION UNITS.
Its reduced size and weight make it also suitable for on-site tests, featuring a rechargeable battery and a case.
Discover DATOSPIR touch
On-screen
help
Software
W20s spirometry
Database
12,000 tests
Internal
Printer
Adults and children
incentives
Curves
Simultaneous F/V and V/T
Integrated weather
station
Connectivity
USB and Bluetooth
Tests and Parameters
Tests
- FCV/Bronchodilation
- VC
- MVV
- Bronchoconstriction
Parameters
- FVC
- FEV0.5
- FEV0.75
- FEV1
- FEV3
- FEV0.5/FVC
- FEV0.75/FVC
- FEV1/FVC
- FEV3/FVC
- FEV1/VC
- PEF
- FEF25%
- FEF50%
- FEF75%
- FEF25-75%
- FEF75-85%
- FET25-75
- FET100
- FEF50/FIF50
- FEV1/FEV0.5
- FEV1/PEF
- FIF50%
- FIVC
- FIV1
- FIV1/FIVC
- FEV1/FIV1
- PIF
- MTT
- PEF/PIF
- Vext
- MvvInd
- FEV6
- FEV1/FEV6
- EPOC index
- Lung age
- ETC...
Transducers
DISPOSABLE LILLY
PRIMARY HEALTHCARE
OCCUPATIONAL MEDICINE
PULMONARY FUNCTION UNITS
This is the most widely-used solution at the moment, because of its accuracy, through the Lilly pressure system, and its disposable system.
Measurement based on pressure difference
Accurate and reliable
Without filters or mouthpieces!
Factory preset
Ergonomic design
Protection against cross contamination
FLEISCH
PULMONARY FUNCTION UNITS
Very precise pressure transducer, used in numerous pulmonary units because of its great accuracy. It requires an antibacterial filter to ensure there is NO TRANSMISSION between patients.
Measurement based on pressure difference
Accurate and reliable
With filters or mouthpieces
TURBINE
PRIMARY HEALTHCARE
OCCUPATIONAL MEDICINE
Measuring transducer through a helix. It is the most economic model for performing a correct spirometry. It requires an antibacterial filter to ensure there is NO TRANSMISSION between patients.
Measurement based on a turbine
Accurate and reliable
With filters or mouthpieces
Incorporated pressure, temperature and humidity
According to ATS/ERS and SEPAR recommendations, to carry out an optimal spirometry, ambient temperature, humidity and pressure factors should be taken into account.
Datospir Touch automatically calculates the atmospheric values with its integrated weather station.
Spirometry quality control
It features an automatic quality-control function with messages that help the technician to provide good instructions to the patient in order to obtain high-quality spirometry tests. It is based on the ATS/ERS qualification system and on the American National Lung Health Education Program (NLHEP) recommendations. QC Prompts and QC Grades.
Quanjer 2012-GLI with LLN and Z-Score
It includes in the report the Quanjer 2012-GLI international.
In the report, there is a chart that helps the technician identify quickly the state of the patient.
References
GLI/QUANJER · SEPAR 2013 · ERS · KNUDSON · CRAPO · ZAPLETAL · MORRIS · AUSTRIA · GUTIERREZ · CASTRO – PEREIRA 2002 · POLGAR-WEN · GHANKINSON-NHANES III · PEREZ-PADILLA · A.J. CRUZ GOLSHAN · GARCIA RIO · CANDELA · PLATINO · THAI 2000 · CASTRO PEREIRA 2007
Optional Modules
PULSE OXIMETRY | BRONCHOCONSTRICTION | MIP-MEP and SNIFF |
---|---|---|
DATOSPIR touch may incorporate a module dedicated exclusively to taking oxygen saturation samples and plethysmographic pulse. This option allows you to take pulse oximetry measurements independently or while a spirometry test is performed. It also lets you visualize the plethysmographic wave in real time and carry out occasional measurements of Oxygen Saturation (SpO2) and Pulse Rate (PR), or long-term studies. | The bronchoconstriction module is an option available with the DATOSPIR touch spirometer. The test can be performed using two different methods: • Normal or continuous method: It consists of administering a patient a certain concentration of medication for a specified amount of time. • Abbreviated method: It consists of administering a patient a certain number of inhalations of a certain concentration. | DATOSPIR touch has an external Maximum Respiratory Pressures module available. It allows for a measurement range of ±295 hPa (±300 cmH2O) in inspiratory tests as well as in expiratory tests, and has several reference values which can be configured by the user. With the SNIFF probe, it can also measure maximum nasal pressures. |
W20s software
DATOSPIR touch incorporates as standard the SIBELMED W20s software, to carry out simple, intuitive and quality spirometry processes:
- Tests: FVC/ Bronchodilation, VC, MVV and bronchoconstriction
- (+40 parameters).
- Simultaneous F/V and V/T graphs.
- Incentive graphs.
- Selection of different automatic diagnoses.
- More than 20 international references.
- Includes the Quanjer 2012-GLI with LLN and Z-score reference values.
- Spirometry quality control.
- Trend reports to view the development of the patient.
- Export data in XML or PDF.
- Management of different databases.
- Compatible with Windows VISTA, 7, 8.1 and 10.
- Complies with the ATS/ERS 2019 recommendations.
Interoperability
The optional module W20sLink allows interoperability with the Hospital Information System (HIS).
Export formats: PDF, XML, DICOM, CDA/HL7.
Customization or OEM available!
At Sibelmed, we have our own in-house R&D&I department, allowing us to customize devices to different levels, depending on the requirements of each customer, as well as the development of OEM projects for companies.
Models
EASY Primary Healthcare · Occupational Medicine | DIAGNOSTIC Respiratory Units | |
---|---|---|
Tests | FVC, VC, MVV, Bronchodilation | FVC, VC, MVV, Bronchodilation, Bronchoconstriction |
Weather station | Temperature | Temperature, Pressure, Humidity |
Connectivity | USB (PC) | Bluetooth and USB (PC) |
Database | Up to 4,000 tests | Up to 12,000 tests |
Charts | F/V or V/T | Simultaneous F/V and V/T |
Optional | Interoperability HL7 · Pulse Oximeter · MIP-MEP · Sniff |
Both models are compatible with the 3 transducers.
Technical features
Measurements | 195 x 270 x 100 mm. |
Weight (without battery or accessories) | 1.25 kg. |
Screen | 640 x 480 pixels and 5.7 inches |
Printer | 112 mm thermal graphic printer. |
Rechargeable battery | Ni-Mh 9.6V > 2000 mAh. Range of approx. 1.5 h |
Power Supply | 100 to 240V, 50 to 60Hz. |
Power | 30W |
Range of measurement (BTPS) Flow Volume | 0 to + 16 l/s 0 to 10 l |
Accessories and consumables
Standard Accessories
- 1 Plastic mouthpiece
- 1 Nose clip
- 1 CD with W20s Software
- 1 instruction manual
- 1 USB Cable (connection to PC)
-
Disposable Model:
1 bag of disposable transducers (25u.)
1 Calibration adapter -
Fleisch/Turbine model:
1 Bag of cardboard mouthpieces (25u.)
Optional Accessories
- 01149 Pediatric mouthpiece adapter
- 08290 Calibration syringe
- 07283 Travel bag
- 02634 Thermal paper (5u.)
Consumable
- 03169 Disposable transducer (50u.)
- 01555 Cardboard mouthpieces (100u.)
- 01569 Plastic mouthpieces (10u.)
- 09698 Bacterial filter (100u.)
- 01149 Pediatric mouthpiece adapter (1u.)
- 02692 Plastic nose clip (5u.)